Call for Service CE40

  • Code: CE40
  • Description:Image quality control test pattern abnormality: The test pattern is not formed normally.
  • Causes:Main charger cleaner Drum cleaner unit LED printer head Image quality sensor (Rear) Transfer belt Spring 1st transfer contact/release clutch 1st transfer roller status detection sensor Image quality sensor LGC board High-voltage transformer (HVT)
  • Remedy:1 Check if there is any abnormality on the hand grips and rods of the main charger cleaner. Correct if there is. 2 Check if the drum is rotated properly by turning the coupling of the cleaner unit. Correct the auger and the surrounding hardware if not. 3 LED printer head • Check the connectors and harnesses between the LGC board (CN357, CN359, CN356, CN358, CN331, CN332, CN329, CN330, CN788, CN787, CN790, CN789, CN792, CN791, CN794 and CN793) and the LED printer head. • Check if there is any stain or scratch on the LED printer head. Clean or correct if there is. 4 Check if there is any stain on the image quality sensor (Rear). 5 Check if the sensor shutter is working properly. 6 Transfer belt Check if the transfer belt is installed in the transfer belt unit properly. Check if the transfer belt is loose or heaving, and correct it if needed. Check if the transfer belt unit is installed in the equipment properly. Check if the transfer belt is properly operated. (ON: FS-03-101 / OFF: FS- 03-151) If the transfer belt rotates normally, check if any abnormal stains (cleaning defects), large scratches or breaking are on the surface of transfer belt by making full rotation of transfer belt. Replace the transfer belt if any. If the transfer belt is not rotating normally, check if the drive gears are damaged or if it contacts the equipment or if the transfer belt cleaning unit is normal. Correct it if needed. 17* 7 Check if any of the springs for supplying power to the transfer belt unit is deformed. Replace the spring if it is deformed. 8 Use “Image quality control abnormal detection counter Y to K display/0 clearing (FS-08-2528 to 2531)” to check the abnormal occurring condition for each color. 9 Check the first pattern detection value for each color of image quality sensor detection value (FS- 05-2758-2 to 5), and identify the color of unit which causing test pattern abnormality. Identify the color of unit by check the value which exceeds “600”. (Sub-code 2: Y, 3: M, 4: C, 5: K) If the detected value of K is normal but that for only Y, those for Y and M, or those for Y, M and C is abnormal, perform the following procedure. -> Check that the phenomenon can be recovered by replacing the 1st transfer contact/release clutch or the 1st transfer roller status detection sensor. 10 Check if the developer unit identified in step 9 has been installed properly. Visually check the installation and assembly status of the developer unit, and correct it if there is any abnormality. 17* 11 Set the values of “Image quality closed-loop control / Contrast voltage (FS-08-2486)” to “0” (Invalid). 12 Perform “Enforced performing of image quality open-loop control (FS-05-2740)”. 13 Output several number of sheets of the image quality control test pattern (FS-04-270) and the list print (FS-30-101), and check the pattern of the color identified in step 9. Is the image normal? Yes 15 No 14 14 Abnormal image Correct the abnormal image. Blank print, Solid print, White banding, Color banding, White spots, Poor transfer, Uneven image density, Faded image (low density), Uneven light distribution, Blotched image. Notes: • Refer to the each troubleshooting for the image. • Blank print: including when one of the YMCK colors is not printed. 16 15 Replace the image quality sensor or LGC board. 16 Set the values of “Image quality closed-loop control / Contrast voltage (FS-08-2486)” to “1” (Valid). 17 Perform “Forced performing of image quality closed-loop control (FS-05-2742).” Is it completed normally? Yes 19 No 18 18 Check and correct it accordingly. 19 Perform “Automatic gamma adjustment”. 20 Clear all “Image quality control abnormal detection counter Y to K display/0 clearing (FS-08-2528 to 2531)”.
Ideal Technologies Toshiba Photocopier Service Center in Bangladesh

Toshiba Photocopy Machines Toner Model

ফটোকপি মেশিনের টোনার কার্ট্রিজ সার্ভিস সম্পর্কিত যেকোন তথ্য জানতে ‍যেকোন সময় কল করুন: 01717146717 (Whatsapp Available)

01717146717অথবা SMS দিয়ে রাখুন ‍আমরা যোগাযোগ করবো ।

SLToshiba Photocopy  Machine ModelToner Model
01T-4590D toner for TOSHIBA e-studio 256, 306, 356, 456, 356SE, 456SE, 506SE T-4590D
02T-4530D toner for TOSHIBA e-studio 255, 305, 355, 455 T-4530D+C
03TOSHIBA 3560, 4560 T-3560
04T3520D toner for TOSHIBA e-studio 350, 450, 352, 452 T-3520D
05 T-FC30C-YMCK toner for TOSHIBA e-studio 2550C, 2051C, 2550C, 2551CT-FC30C-K
T-FC30C-Y
T-FC30C-M
T-FC30C-C
T-FC30P-K
T-FC30P-M
T-FC30P-Y
T-FC30P-C
06T-2450D toner for TOSHIBA e-studio 195, 223, 225, 243, 245 T-2450D
07T-2450CS-10K toner for TOSHIBA e-studio 223/243  T-2450CS
08T-2340D toner for TOSHIBA e-studio 230 280 232 282 233 283 T-2340D
09TOSHIBA 2060, 2860, 2870 2060/2507C+P
10T-1810D toner for TOSHIBA e-studio 181, 182, 211, 212 T-1810D
11T-1800CS-10K toner for TOSHIBA e-studio 18T-1800-CS 10k
12T-1800DS toner for TOSHIBA e-studio 18 T-1800 DS
13T-1640D toner for TOSHIBA e-studio 163, 165, 203, 205 T-1640D
14TOSHIBA 166, 206 T-1640D
15T-3008C/P/E toner for TOSHIBA e-studio 2008A, 2508A, 3008A, 3508A, 4508A, 5008AT-3008E
16T-2309C/P/E toner for TOSHIBA e-studio 2303AM, 2309A, 2803AM, 2809AT-2309C
17T-2309C toner for TOSHIBA e-studio 2303A, 2309A, 2803A, 2809A    T-2309C
18T-5070C/P toner for TOSHIBA e-studio  257, 307, 357, 457T-5070P+C
(C-6200)
19T-3008P toner for TOSHIBA e-studio 4508A, 2508A, 3008AT-3008P
20T-2309P toner for TOSHIBA e-studio 2809a, 2303a, 2803aT-2309P
21T-3008C toner for TOSHIBA e-studio 2508A, 3008A, 3508A, 4508A, 5008AT-3008C
22T-5018C/P toner for TOSHIBA e-studio 2518A, 3018A, 3518A, 4518A, 5018AT-5018C
23T-1810C toner for TOSHIBA e-studio 181, 182, 211, 212, 242T-1810C
24T-2450D toner for TOSHIBA e-studio 223, 243T-2450CS
25T-2507C toner for TOSHIBA e-studio 2006, 2306, 2506, 2307, 2507T-2507C
26 T-FC415C-YMCK toner for TOSHIBA e-studio 2010AC 2510AC 2515AC 3015AC 3515AC 4515AC 5015ACT-FC415C-K
T-FC415C-M T-FC415C-C T-FC415C-Y
27 T-FC415P-YMCK toner for TOSHIBA e-studio 2010AC 2510AC 2515AC 3015AC 3515AC 4515AC 5015ACT-FC415P-K
T-FC415P-M T-FC415P-C T-FC415P-Y
28T-FC50P-YMCK Toshiba e-STUDIO 2551C 2051C 2050C 2550C 3055C 3555CSE 4555CSET-FC50P-Y T-FC50P-M T-FC50P-C T-FC50P-K
29T-FC505P-YMCK Toshiba e-STUDIO 2000AC 2500AC 2505AC 3005AC 3505AC 4505AC 5005AC.T-FC505P-Y T-FC505P-M T-FC505P-C T-FC505P-K
30T-FC505C-YMCK Toshiba e-STUDIO 2000AC 2500AC 2505AC 3005AC 3505AC 4505AC 5005AC.T-FC505C-Y T-FC505C-M T-FC505C-C T-FC505C-K
Search products
Back to Top
Product has been added to your cart